ETHERMA und myPV News
|Support

AC•THOR 9s – Operation with 3 single-phase heating elements

Our "Support" section offers many practical tips that will help you with the installation and commissioning of our devices.

The load control of 3 single-phase heating elements is a special form of operating mode M1 for hot water.

CAUTION:

This is to be clearly distinguished from operating mode M2 "Layer Charging," where load control is switched to another 3-phase consumer using an external opener and a closer!

The following instructions from the operating manual are important:

Solution

The regular operation for 3 single-phase heating elements can be set with a single adjustment. Simply switch the "Load Priority" accordingly under "Settings" (gear symbol).

Good to know

Tip: Connect the topmost heating element to the control output OUT-3 of the AC•THOR 9s. If you accidentally did not follow the order, simply switch the consumption plugs. This saves rewiring!

More articles

General

Use dynamic electricity tariffs for heat with the my-PV DTO and HEA•THOR

Using low-cost electricity prices from the exchange market for heating is no longer a vision of the future!

Read more...

References

Climate protection award for a heritage multi-family house: Photovoltaic heat in a historic building

A 150-year-old house has been designed to be as energy-independent as possible – earning it a Climate Protection Award.

Read more...

Partner

New Supplier for my-PV Devices: The REISSER Group

We are pleased to announce that the REISSER Group is now an official supplier of my-PV devices.

Read more...