)
AC•THOR 9s – Operation with 3 single-phase heating elements
Our "Support" section offers many practical tips that will help you with the installation and commissioning of our devices.
The load control of 3 single-phase heating elements is a special form of operating mode M1 for hot water.
CAUTION:
This is to be clearly distinguished from operating mode M2 "Layer Charging," where load control is switched to another 3-phase consumer using an external opener and a closer!
The following instructions from the operating manual are important:
)
Solution
The regular operation for 3 single-phase heating elements can be set with a single adjustment. Simply switch the "Load Priority" accordingly under "Settings" (gear symbol).
Interesante
Tip: Connect the topmost heating element to the control output OUT-3 of the AC•THOR 9s. If you accidentally did not follow the order, simply switch the consumption plugs. This saves rewiring!
More articles
)
General
Utilice tarifas eléctricas dinámicas para calefacción con el my-PV DTO y HEA•THOR¡Utilizar electricidad barata del mercado para calefacción ya es una realidad, no solo la electricidad renovable de un sistem
Leer más...)
Referencia
Premio de protección del clima para una casa multifamiliar patrimonial: Energía solar fotovoltaica en un edificio históricoUna casa de 150 años, diseñada para ser casi autosuficiente en energía, ganó un Premio de Protección del Clima.
Leer más...)
Socios
Nuevo proveedor para dispositivos my-PV: el Grupo REISSERNos complace anunciar que el Grupo REISSER ahora es un proveedor oficial de dispositivos my-PV.
Leer más...