Error : Hot water securing
If the error 102 message is displayed on the AC•THOR /AC•THOR 9s , this means that the hot water securing function is active, but no temperature sensor has been connected or activated yet.
To correct this error, connect the sensor to the AC•THOR and activate it via the display.
To do this, click on settings (gearwheel symbol), scroll to the item "sensors" and select it.
You will then see the serial number of the connected sensor and its current temperature on the display. Click once on this line. Now the sensor number is displayed to the right of the displayed temperature. This sensor is now active. Finally, save the setting.
TIP: If the optional temperature safeguard is not used, the heat generator has a thermostat and you only want to use excess energy anyway, then the installation of the temperature sensor is not necessary at all!
Our "Support" section offers many useful practical tips that will help you install and commission our solutions.
Furthermore, you will learn about all the most important innovations of my-PV products.
More articles
Références
Ancienne ferme irlandaise transformée en maison alimentée par l’énergie solaireIndépendance grâce au SOL•THOR : production autonome d’eau chaude dans une ancienne ferme irlandaise.
lire la suite...Généralités
Utilisez vous-même l’énergie de votre centrale solaire de balcon au lieu de la donner !Quatre variantes montrent que, dans une centrale solaire de balcon de 2 kWp, la chaleur devient la clé pour exploiter tout so
lire la suite...Références
Chauffage photovoltaïque en deux versions pour l’eau chaude et le chauffageUn système PV raccordé et un système PV autonome produisent l’eau chaude et soutiennent le chauffage en Forêt-Noire.
lire la suite...