Error : Hot water securing

If the error 102 message is displayed on the AC•THOR /AC•THOR 9s , this means that the hot water securing function is active, but no temperature sensor has been connected or activated yet.

To correct this error, connect the sensor to the AC•THOR and activate it via the display.

To do this, click on settings (gearwheel symbol), scroll to the item "sensors" and select it.

You will then see the serial number of the connected sensor and its current temperature on the display. Click once on this line. Now the sensor number is displayed to the right of the displayed temperature. This sensor is now active. Finally, save the setting.

TIP: If the optional temperature safeguard is not used, the heat generator has a thermostat and you only want to use excess energy anyway, then the installation of the temperature sensor is not necessary at all!

Our "Support" section offers many useful practical tips that will help you install and commission our solutions.

Furthermore, you will learn about all the most important innovations of my-PV products.

More articles

Généralités

France : l’autoconsommation photovoltaïque gagne en importance malgré la PPE3

Avec la PPE3 (2026), la France mise sur le nucléaire ; le PV reste clé, davantage pour l’autoconsommation locale.

lire la suite...
House with beige walls, red roof, and solar panels. Surrounded by greenery, clear sky above.

Références

Réduisez la consommation de gaz avec SOL•THOR

Maison individuelle économise du gaz grâce à une génération de chaleur autonome à partir de l'énergie photovoltaïque

lire la suite...
Modern building exterior with large glass windows, surrounded by trees. The pathway is lined with white rectangular tiles.

Références

Énergie verte pour Casa Verde

Casa Verde montre comment architecture moderne, confort élevé et chaleur photovoltaïque peuvent être combinés.

lire la suite...