my-PV GmbH
|Assistance

Error : Hot water securing

If the error 102 message is displayed on the AC•THOR /AC•THOR 9s , this means that the hot water securing function is active, but no temperature sensor has been connected or activated yet.

To correct this error, connect the sensor to the AC•THOR and activate it via the display.

To do this, click on settings (gearwheel symbol), scroll to the item "sensors" and select it.

You will then see the serial number of the connected sensor and its current temperature on the display. Click once on this line. Now the sensor number is displayed to the right of the displayed temperature. This sensor is now active. Finally, save the setting.

TIP: If the optional temperature safeguard is not used, the heat generator has a thermostat and you only want to use excess energy anyway, then the installation of the temperature sensor is not necessary at all!

Our "Support" section offers many useful practical tips that will help you install and commission our solutions.

Furthermore, you will learn about all the most important innovations of my-PV products.

More articles

Références

New feed-in regulations in the Netherlands require a rethink

A Dutch homeowner minimizes feed-in fees by utilizing surplus PV energy to heat water.

lire la suite...

L'entreprise

SOL•THOR wins German Design Award 2025

The DC Power Manager SOL •THOR has received the German Design Award in the category “Excellent Product Design”.

lire la suite...

Généralités

Minimizing feed-in costs in the Netherlands

The Netherlands introduced a fee for feeding electricity into the grid. Fees can be reduced by increasing self-consumption.

lire la suite...