Error : Hot water securing

If the error 102 message is displayed on the AC•THOR /AC•THOR 9s , this means that the hot water securing function is active, but no temperature sensor has been connected or activated yet.

To correct this error, connect the sensor to the AC•THOR and activate it via the display.

To do this, click on settings (gearwheel symbol), scroll to the item "sensors" and select it.

You will then see the serial number of the connected sensor and its current temperature on the display. Click once on this line. Now the sensor number is displayed to the right of the displayed temperature. This sensor is now active. Finally, save the setting.

TIP: If the optional temperature safeguard is not used, the heat generator has a thermostat and you only want to use excess energy anyway, then the installation of the temperature sensor is not necessary at all!

Our "Support" section offers many useful practical tips that will help you install and commission our solutions.

Furthermore, you will learn about all the most important innovations of my-PV products.

More articles

Généralités

Évaluation annuelle du bâtiment de l'entreprise solaire-électrique 2025

Pour sa 4e année complète, le bâtiment solaire-électrique de my-PV confirme encore son excellente efficacité.

lire la suite...
Close-up of a digital electricity meter with a small display screen, labeled buttons, and a visible barcode.

Généralités

Fin du « compteur qui tourne à l’envers » : une nouvelle étape pour l’autoconsommation en Wallonie

En Wallonie, le compteur qui tourne à l’envers prendra définitivement fin le 31 décembre 2030.

lire la suite...
Two men holding a certificate stand in a room with solar equipment and a sign that reads "Empowering the Solar Future."

L'entreprise

my-PV re-certifié selon ISO 9001:2015

En 2026, my-PV a de nouveau été recertifié avec succès selon ISO 9001:2015.

lire la suite...